SCANNER OPERATION
Host Scanner Commands
³118015
Enable D/E Disable Command. - The scanner will
disable scanning after it receives an ASCII “D” from
the host device. It will enable scanning when it
receives an ASCII “E”.
³118005
* Disable D/E Disable.
³118211
Enable Z/R Type D/E Simulation - The scanner
will disable scanning after it receives an ASCII “Z”
from the host device. It will enable scanning when it
receives an ASCII “R”.
³118201
* No Z/R Type D/E Simulation
³118014
Enable F/L Laser Command - The scanner will
turn off the laser after the scanner receives an
ASCII “F” character. The laser will turn on after it
receives an ASCII “L” character.
³118004
* Disable F/L Laser Command
³118115
Use DTR Scan Disable - The scanner will monitor
the DTR input to determine if scanning should be
allowed. A +12V “active” level enables decoding.
A -12V “inactive” level disables decoding.
³118105
* Do Not Use DTR Scan Disable - Do not monitor
the DTR input.
³118110
Activate DC2 Character - Scanning will be initiated
with the receipt of a DC2 character (^R, 124).
³118100
* Do Not Activate on DC2 Character