Unitech MP200 Especificações Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 26
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 20
Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
40
Copyright 2008 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
41
B.2.0 Magnetic Card Read command strings
Six Commands strings are provided, to read the magnetic cards. These commands
are summarized in the tables below. The general syntax for commands is as follows:
Command String – General Syntax <ESC><’M’><n>< n> Track #CR
Command String - Example <ESC><’M’> ‘9’ ‘ 9’ 1 CR
Table B.1 – Magnetic Card Read Command Strings – general form
The ESC-M command turns on the power to the MC Reader
The next two bytes, <nn> are used to set the MC reader’s timer. “01” through “99”
are valid timer settings and “00” disables the timer.
The printer aborts and transmits the time-out error message, if the operator fails to
swipe a card within the time period set by the host application.
On timeout printer aborts the swipe process, transmits timeout error message and
turns off the <READING> LED.
A good magnetic card swipe automatically terminates the read process.
Magnetic Card Command String Description
ESC – M - nn - 1 – CR (CR = Enter) Read Track1 only
ESC – M - nn - 2 – CR Read Track2 only
ESC – M - nn - 3 – CR Read Track3 only
ESC – M - nn - 4 – CR Read Track1 and Track2 simultaneously
ESC – M - nn - 5 – CR Read Track2 and Track3 simultaneously
ESC – M - nn - 6 – CR Read Tracks 1,2 and 3 simultaneously
ESC – C Cancel MC Read process
nn = ASCII “01” through “99” seconds
nn = “00” disables the MC reader timer
Table B.2 – Magnetic Card Read Command Strings - Details
B.3.0 Magnetic Card Data Output Format
The track data retrieved from a magnetic card is transmitted to the host in
ISO7811 ASCII format as summarized in the table below.
The rst four characters (“%/1/”) ag the track number, the track data follows the
ag string, terminated with ‘?’-CR-LF.
‘%;+’ are the track start sentinel characters, While ‘?’ is the end of track sentinel
character.
If no data is available for a track that data eld will be empty. If an Error is
encountered on any track a single ‘E’ will be the output for that tracks data eld.
Track1 Track 2 Track 3
%/1/ Data ?CRLF ;/2/ Data ?CRLF +/3/ Data ?CRLF
Table B.3 - ISO 7811 ASCII Format
B.4.0 Magnetic Card Read Error Messages
The characters <%> and <E> preface all error messages. Following these two
characters is a comma, the error number in ASCII (01 through 99), another comma,
English description of the error encountered and nally CR-LF terminating the <Error
Message> string. The syntax is as follows:
Error Message ( General Form) <%><E>, nn , Error text in ASCII, <CR> <LF>
Table B.4 – Error Message – General Form
Where nn is error number encountered. The printer may transmit Four (4) types of
Read Error messages. The following messages terminated with CR-LF are returned
by the rmware:
Error # Error Message Transmitted
05 Time-out Expired
07 Invalid Track Number
08 Unsupported Track Selected
09 Cancel Request
Table B.5 – Error Message – Specic Examples
Vista de página 20