MS860G WiFi Manual 35
SCANNER CONFIGURATION MANAGER
Bar Code Symbologies, continued
EAN-8
• Enabled toggles the ability for the scanner to read EAN-8 on or off.
Default is “Yes”.
• Code ID is a user-definable identification letter for EAN-8,
which is referred to in the “Use Code ID” function on page 25.
Default is
letter “FF”.
• Send Leading Digit toggles sending or not sending a leading
(‘start bar code’) digit.
Default is “Send”.
• Send Check Digit toggles sending or not sending a check digit.
Default is “Send”.
Code 11
• Enabled toggles the ability for the scanner to read Code 11 on or off.
Default is “Yes”.
• Code ID is a user-definable identification letter for Code 11,
which is referred to in the “Use Code ID” function on page 25.
Default is
letter “J”.
• Send Check Digit Number defines the check digit.
Default is “Send”.
• Send Check Digit toggles sending or not sending a check
digit.
Default is “Send”.
• Minimum Length defines the minimum length the user will
accept for a valid bar code.
Default is “3”.
• Maximum Length defines the maximum length the user will
accept for a valid bar code.
Default is “48”.
Delta Code
• Enabled toggles the ability for the scanner to read Delta Code on or off.
Default is “No”.
• Code ID is a user-definable identification letter for Delta Code,
which is referred to in the “Use Code ID” function on page 25.
Default is
letter “D”.
• Calculate Check Digit toggles whether or not to calculate a
check digit.
Default is “Yes”.
• Send Check Digit toggles sending or not sending a check
digit.
Default is “Send”.